NC Solar/Wind Permitting Standards

Model Wind Ordinance

AI summary · 11/22/2026

This is a model ordinance, not a rebate or a permit, so it gives you no money directly, but it shows what a wind-friendly town's rules might look like. For a small turbine (a single unit of 20 kW or less), the model sets no setback from your own occupied buildings and asks for 1.5 times turbine height from neighbors' homes and public roads and 1.1 times from neighbors' property lines. Because it has no legal force, check with your city or county planning office about the rules that actually apply to you.

The model ordinance gives you a template for what local governments may require, and it omits lot size and height limits in favor of minimum setbacks, which can make small and medium projects easier to site. Typical applications include system size, type and location, a detailed site plan, proof of code compliance, an environmental assessment, a decommissioning plan and any agreements among participating parties. Designs should meet industry standards and all codes, use a non-obtrusive color such as white, off-white or gray, carry no lighting beyond FAA requirements, and display no advertising; always confirm the adopted local rules, since the model is not binding.

This is a non-binding model siting ordinance published in July 2008 by the North Carolina Wind Working Group, a coalition of state government, nonprofit and wind industry organizations, to guide local governments writing their own wind rules, and it has no associated funding. It classifies systems as small (single turbine up to 20 kW), medium (over 20 kW to 100 kW) or large (over 100 kW), sets setbacks as multiples of turbine height by system type, and limits large-system sound to 55 dBA at non-participating occupied buildings, with waivers possible when all affected parties agree. It applies to all sectors, including residential, commercial, agricultural, institutional and government, and each locality decides whether to adopt it.

Program details

Program ID
3051
Last updated
8/11/2023

Eligibility

Sectors
commercial industrial investor-owned utility local government nonprofit municipal utilities residential cooperative utilities schools state government federal government agricultural institutional
Technologies
wind (all) wind (small)

Program summary

Note: This model ordinance was designed to provide guidance to local governments that wish to develop their own siting rules for wind turbines. While it was developed as part of a cooperative effort involving several state agencies, the model itself has no legal or regulatory authority.

In July, 2008 the North Carolina Wind Working Group, a coalition of state government, non-profit and wind industry organizations, published a model wind ordinance to provide guidance for communities seeking to promote wind energy. For the purposes of this model, wind-energy systems are classified as "small" if they consist of a single wind turbine with a rated generating capacity of 20 kilowatts (kW) or less, "medium" if they have a total rated capacity of more than 20 kW but not greater than 100 kW and "large" if they have a total rated capacity of more than 100 kW.

Height Requirements: Wind turbine height is the distance measured from grade at the center of the tower to the highest point of the turbine rotor or tip of the turbine blade when it reaches its highest elevation. The setbacks (addressed below) are minimum requirements, designed to protect public safety and mitigate the impacts of noise and shadow flicker. By addressing these concerns through minimum setback requirements, the model wind ordinance omits lot size requirements and height restrictions.

Setbacks: The setback is calculated by multiplying the required setback number by the wind turbine height and measured from the center of the wind turbine base to the property line, building or road. Setbacks are generally determined by the following table:

Wind Energy Facility Type Occupied Buildings on Participating Landowner Property Occupied Buildings on Non-Participating Landowner Property Property Lines on Non-Participating Landowner Property Public Roads
Small System 0.0 1.5 1.1 1.5
Medium System 1.1 2.0 1.5 1.5
Large Scale 1.1 2.5 1.5 1.5

Setbacks may be waived under certain conditions when all affected parties agree to different terms.

Noise Requirements: Noise and shadow flicker issues for small and medium wind energy facilities are addressed by setbacks, or will be addressed by existing noise ordinances. Audible sound from a large wind energy facility should not exceed fifty-five dBA, as measured at any occupied building of a non-participating landowner. Restrictions may be waived under certain conditions.

Installation and Appearance: The installation and design of the wind energy facility should conform to applicable industry standards and meet all local, state and national codes. The wind energy facility should be a non-obtrusive color such as white, off-white or gray, should not be artificially lighted, except to the extent required by the Federal Aviation Administration and should not display advertising or decorative items.

The permit application should contain information about the size, type and location of the wind energy facility; a detailed site plan; proof of compliance with local, state and federal regulations; an environmental assessment; decommissioning plans and any agreements among participating parties.