Green Building and Energy Reduction Standards for State Agencies
This program does not apply to homeowners—it requires Washington state government facilities, schools, and affordable housing projects to meet green building standards like LEED Silver or the Washington Sustainable Schools Protocol, which mandates at least 10% energy reduction beyond state code for public K-12 schools.
If your firm designs or builds state agency facilities, K-12 school projects, or affordable housing receiving state assistance, you must meet LEED Silver certification or equivalent sustainable standards; the Department of Enterprise Services and Office of Superintendent of Public Instruction provide guidelines, and exemptions require documented justification to the state.
This mandate, codified in RCW 39.35D and related statutes, requires new state facility construction and renovals over 5,000 sq. ft. (with renovation costs exceeding 50%) to achieve LEED Silver; public K-12 schools must follow the Washington Sustainable Schools Protocol or LEED for Schools with 10% energy savings beyond code; the Department of Enterprise Services administers guidelines and reports biennially to the legislature on energy and water consumption through 2016, with state agencies submitting annual data by June 1st.
Program details
- Program ID
- 1914
- Last updated
- 6/6/2024
Eligibility
- Sectors
- state government
- Technologies
- solar - passive solar water heat solar space heat solar photovoltaics wind (all) biomass geothermal heat pumps combined heat & power daylighting wind (small) hydroelectric (small) comprehensive measures/whole building other ee
Program summary
Requirements
With the passage of Engrossed Substitute Senate Bill 5509 – Related to High Performance Green Building, State facilities in Washington must be designed and built to the US Green Building Council's Leadership in Energy and Environmental Design (LEED)Silver standards. The bill has been transferred into statute at RCW 39.35.D.
All new major facility project construction and renovation projects over 5,000 sq. ft., where the renovation costs exceed 50%, as defined in RCW 39.94.020, must be designed, constructed, and certified to at least the LEED Silver standard.
The Department of Enterprise Services (DES) was given a leadership role in the development of procedures to ensure the state is successful in this effort. In consultation with affected public agencies, the DES develops and issues guidelines for administering this policy. The purpose of the guidelines is to define a procedure and method for employing and verifying activities necessary for certification to at least theLEED Silver standard for major facility projects.
DES is also responsible for reporting to the Governor and the Legislature related to progress implementing this policy. Public agencies, must monitor and document ongoing operating savings resulting from major facility projects designed, constructed, and certified.
Schools
Public K-12 school construction projects receiving state assistance must be built to the Washington Sustainable Schools Protocol (WSSP), or LEED for Building Design and Construction (Schools). The WSSP requires a 10% reduction in energy use beyond what is required by the Washington State Energy Code. The Office of Superintendent of Public Instruction will enforce these guidelines and provide relevant information to school districts. The GA will develop and issue guidelines for state agencies.
Affordable Housing
The Department of Commerce (formerly the Department of Community, Trade, and Economic Development) has adopted the Evergreen Sustainable Development Standard, and set a minimum level of sustainable performance for projects applying to the Housing Trust Fund (HTF).
Exemptions
Some projects may be exempt based on the following criteria:
- Projects for which the applicable agency and the design team determine the LEED Silver standard or the Washington sustainable school design protocol to be not practicable;
- Transmitter buildings, pumping stations, hospitals, research facilities primarily used for sponsored laboratory experimentation, laboratory research, or laboratory training in research methods, or other similar building types as determined by the department.
If LEED Silver is not practicable for a project, the applicable agency must determine if any LEED standard is practicable for the project. If LEED standards or the Washington Sustainable School Design Protocol are not followed for any reason, the applicable agency must report these reasons to the department.
Annual Energy and Water Consumption Reporting
Buildings owned by a public agency are required to provide energy and water consumption, as well as renewable energy and water capture qualities in an annual report to DES by June 1st of each year. This is required through 2016 per the RCW 39.35D statute. If the owner has had difficulties with collecting the actual electricity and/or heating energy (gas, steam, hot water, etc.) data, then a Metering and Measurement Report must also be submitted. This report should also be submitted if some or all of the data is prorated.
This data is compiled and presented in theBiennial Green Building Report to the legislature (up to 2016).